  series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 1 of 10 north america only features: models single output model max output power (w) output voltage range (v) output current (a) input voltage (vac/hz) input voltage (vdc) mode of operation efficiency (%) 115 vac 230 vac 277 vac amer120 - 50250 c az 125 36 - 50 0 - 2.5 90 - 305/47 - 440 13 0 - 430 constant current 87 88 86 constant voltage 87 88 88 amer120 - 36340 c az 122.4 24 - 36 0 - 3.4 90 - 305/47 - 440 13 0 - 430 constant current 87 88 88 constant voltage 87 88 88 amer120 - 24500 c az 120 12 - 24 0 - 5 90 - 305/47 - 440 13 0 - 430 constant current 85 86 87 constant voltage 86 86 87 add suffi x - f no dimming option exceeding the maximum output power will permanently damage the converter . the dimming feature is not supported when units are used in constant voltage mode only, aimtec suggests to order - f no dimmin g option in the case. in constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. all models can be ordered with optional north american colour input wires ( black (l) , white (n) , green (gnd)) . a dd C na to part number when ordering. note: aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25c, humidity<75%, nominal input voltage (115/230/277vac) and at rated output load unless otherwise specified. see http://www.aimtec.com/terms - sale amer120 - cazs ac/dc led drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities w ith the levels listed in the safety table. applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to dirty electrical conditions which would subject any of the above models to excessive voltages surges or spikes, ma y damage or cause early life failure of product. in this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of aimtec device to ensure the longevity of the products. failure to identify excessive li ne surges violations prior to installation may damage sensitive equipment permanently. input specifications parameters conditions typical maximum units current (full load) 115 vac 1800 ma 230 vac 800 ma 2 77 vac 700 ma inrush current <2ms (cold start) 115 vac 45 a 230 vac 60 a 2 77 vac 70 a leakage current i/o 0. 2 5 ma i/fg, o/fg 3.5 ma power f actor 115 vac 0.98 2 3 0 vac 0.94 2 77 vac 0.92 external fuse recommended slow blow type 3 a start - up time 900 ms output specifications parameters conditions typical maximum units current accuracy 3 % line regulation ll - hl 2 % ? constant current or constant voltage led driver or converter ? short circuit protection ? over current protection ? input range 90 - 305 vac/47 - 440hz ? waterproof case rated ip6 8 ? 115vac operating temperature - 5 0 to 85c ? 230vac operating temperature - 55 to 85c ? dimmable via resistive ? 5 years limited warranty ? power factor correction ? high efficiency up to 88 % click on series name for product info on aimtec.com
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 2 of 10 north america only load regulation 0 - 100% load 3 % ripple & noise 20mhz bandwidth 1 50 mv p - p hold - up time 80 m s current adjustment range 100 - 10 % minimum load voltage see the models table ripple and noise are measured at 20mhz bandwidth by using a 0.1f (m/c) or (c/c) and 47f (e/c) parallel capacitor. note: from 0% to 10% dimming adjustment signal instability may be present. isolation specifications parameters conditions typical rated units tested voltage i/o 3sec 3750 vac i/fg 2000 vac o/fg 500 vac isolation r esistance 500vdc >1000 m general specifications parameters conditions typical maximum units switching frequency 125 khz over current protection amer120 - 50250 c az 2.57 a amer120 - 36340 c az 3.47 amer120 - 24500 c az 5.07 over voltage protection refer to constant current vs. constant voltage mode curve short circuit protection continuous short circuit restart auto recovery operating temperature ( see derating table ) (115vac) - 5 0 to +85 o c (230vac) - 55 to +85 o c cold start - up time - 55c 30 sec maximum case temperature 100 o c storage temperature - 55 to +95 o c temperature coefficient 0.02 % / o c cooling free air convection humidity 95 % rh case material aluminum potting epoxy (ip68 rated) wires ul1015 18awg input & 14awg output *20cm weight 900 g dimensions (l x h x w) 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm mtbf >400,000 hrs (mil - hdbk - 217f at +25c) safety specifications parameters agency approvals ul, ce standards ul8750, ul60950 - 1 , en55022, class b, en60529(ip68) information technology equipment en55022 class b harmonic current emissions iec/en 61000 - 3 - 2 , class c voltage fluctuations and flicker iec/en 61000 - 3 - 3, (en60555 - 3) electrostatic discharge immunity iec 61000 - 4 - 2 level 3 rf, electromagnetic field immunity iec 61000 - 4 - 3 level 2 electrical fast transient / burst immunity iec 61000 - 4 - 4 level 2 surge immunity iec 61000 - 4 - 5 level 3 rf, conducted disturbance immunity iec 61000 - 4 - 6 level 2 power frequency magnetic field immunity iec 61000 - 4 - 8 level 1 voltage dips , short interruptions immunity iec 61000 - 4 - 11
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 3 of 10 north america only dimensions wire connection: analog (resistive) dimming application circuit wire connection brown ac l blue ac n green ground red +v output black - v output blue (dimming) + vs dimming white (dimming) - vs dimming model number maximum pot value (k) amer120 - 50250 c az 18.22 amer120 - 36340 c az 2 2.10 amer120 - 24500 c az 34.31 59 . 00 ( 2 . 32 ) 181 . 00 ( 7 . 13 ) 47 . 00 ( 1 . 85 ) 200 . 00 ( 8 . 00 ) 200 . 00 ( 8 . 00 ) 2 . 30 ( 0 . 09 ) end view top view side view input / output wires are 18 awg 20 cm 41 . 00 ( 1 . 73 ) 8 . 00 ( 0 . 32 ) 11 . 00 ( 0 . 43 ) 4 . 00 ( 0 . 16 ) 23 . 00 ( 0 . 91 ) measurements in millimeters ( inch ) case tolerance : 0 . 5 ( 0 . 02 ) 27 . 00 ( 1 . 06 ) tc a m e r 1 2 0 - a z n 1 s t l e d + v o u t 1 1 - v o u t r e d b l a c k a c b l u e l b r o w n g r e e n b l u e w h i t e p o t
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 4 of 10 north america only analog (0 - 10v) dimming application circuit pwm ( 1khz) dimming application circuit derating - 4 0 - 2 0 0 2 0 4 0 6 0 8 0 1 0 0 1 0 0 8 0 6 0 4 0 2 0 0 f r e e a i r c o n v e c t i o n 5 5 o c s a f e o p e r a t i n g a r e a a m b i e n t t e m p e r a t u r e o c 8 5
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 5 of 10 north america only e fficiency vs. input voltage and output current (cc load) amer120 - 50250 c az amer120 - 36340 c az
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 6 of 10 north america only efficiency vs. input voltage and output current (cc load) continued amer120 - 24500 c az pfc value vs. output load current (cc load) amer120 - 50250 c az
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 7 of 10 north america only pfc value vs. output load current (cc load) amer120 - 36340 c az amer120 - 24500 c az
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 8 of 10 north america only constant current mode vs. constant voltage mode amer120 - 50250 c az amer120 - 36340 c az
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 9 of 10 north america only constant current mode vs. constant voltage mode amer120 - 24500 c az ou tput current vs. radj amer120 - 50250 c az
series am er120 - c az up to 5a | ac - dc / dc - dc | led driver / converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec ( 924 6832) f 052.1e r3. q 10 of 10 north america only output current vs. radj amer120 - 36340 c az amer120 - 24500 c az note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an ambient temperature of 25c, humidity<75%, n ominal input voltage and at rated output load unless otherwise specified. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary a nd may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this da tasheet. 7. warranty is in accordance with aimtecs standard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AMER120-36340CAZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X